1-28 (E)
VPL-FH60
1-6-17. In-polarizer (R)/(G)/(B)
Assemblies
3
Screw
(B2
)
5)
1
Screw
(B2
)
5)
5
Screw
(B2
)
5)
Screw
(B2
)
5)
Screw
(B2
)
5)
Screw
(B2
)
5)
Elongate hole
Elongate hole
Elongate hole
2
In-polarizer (B)
assembly
In-polarizer (R)
assembly
In-polarizer (G) assembly
In-polarizer (B) assembly
4
In-polarizer (G) assembly
6
In-polarizer (R) assembly
$
If the screw is tightened strongly from the beginning, the in-polarizer is moved and
the misalignment of angle occurs.
When tightening the screw, hold the adjustment knob firmly and lightly tighten the screw at first.
Then, gradually increase the tightening force and firmly tighten the screw in the end.
When attaching the in-polarizer (R)/(G)/(B) assemblies, attach them so that each screw is located
at the center of the elongate hole.