2-6.4. RF INPUT - SUB HUE/SUB COLOR
ADJUSTMENT
Preparation:
• Input a Color Bar signal to RF (75 IRE 75%).
• Set picture mode: single (FULL) (PRO MODE Reset).
• Picture:
Max
1. Set to Service Mode and adjust as follows:
NO. Name
Control Function
Avg. Data
01 RGBS
R ON
7
2. Connect an oscilloscope to pin 5 of CN9001 (B. DRV) on the
CX Board.
3. Adjust color according to Service Mode for SCOL.
4. Adjust color according to Service Mode for SHUE.
NO. Name
Control Function
03 SCOL
SUB COLOR
04 SHUE
SUB HUE
2103-1
VB4
VB3
VB2
VB1
COLOR: VB1 < VB4 (=20mV ± 200 mV)
HUE: VB2 < VB3 (=20mV ± 200 mV)
5. Write data into memory.
2170P-4
2-7. WHITE BALANCE (CRT) AND SUB BRIGHT ADJUSTMENT
Preparation
• Input an all white 480I (15.734 KHz) signal into the VIDEO 1 input terminal to perform the White Balance (highlight, cut-off) adjustments. The
parameters to adjust are in the CXA2170P1 in Service Mode.
• Set Picture Mode: Single (FULL) ( POR MODE Reset)
• Picture:
Max
• Color:
Min