5-47
MVC-FD100/FD100H/FD200/FD200H
7.
Self Diagnosis Code
5.
Switch Check (3)
Page 2
Addresses 55, 56
Using method:
1) Select page: 2, addresses: 55, 56.
2) By discriminating the display data, the pressed key can be
discriminated.
Address
Data
00 to 12
13 to 3A
3B to 62
63 to 87
88 to B3
B4 to E0
E1 to FF
55
CONTROL DOWN
CONTROL UP
DISPLAY
FOCUS
(KEY AD1)
(PK-61 board)
(PK-61 board)
(PK-61 board)
(PK-61 board)
No key input
(IC404
ul
)
(S701)
(S701)
(S702)
(S711)
56
CONTROL RIGHT CONTROL LEFT CONTROL SET
FLASH
PROGRAM AE LCD BACK LIGHT (OFF) LCD BACK LIGHT (ON)
(KEY AD2)
(PK-61 board)
(PK-61 board)
(PK-61 board)
(PK-61 board)
(PK-61 board)
(PK-61 board)
(PK-61 board)
(IC404
i;
)
(S701)
(S701)
(S701)
(S705)
(S707)
(S709)
(S709)
6.
LED Check
Using method:
1) Select page: 2, address: 06, and set data: 02.
2) Check that all LED except for the ACCESS LED are lit.
3) Select page: 2, address: 06, and set data: 00.
Page 2
Address 06
Data 02
5-47 E
Display Code
C:32:01
C:13:01
E:91:01
E:61:00
E61:10
Countermeasure
Change the disk and turn off the main
power then back on.
Replace the floppy disk or “Memory
Stick”.
Format the floppy disk or “Memory
Stick” with the MVC-FD100/FD200.
Checking of flash unit or replacement of
flash unit
Checking of lens drive circuit
Cause
Defective floppy disk.
• The type of floppy disk that cannot be
used by this machine, is inserted.
(Such as 2DD)
• Data is damaged.
• Unformatted disk or “Memory Stick”
is inserted.
Abnormality when flash is being
charged.
When failed in the focus initialization.
Caution Display During Error
DRIVE ERROR
DISK ERROR
MEMORY STICK ERROR
Flash LED
Flash display
Flashing at 3.2 Hz
—
Note :
The error code is cleared if the battery is removed, except defective flash, unit.
*1: When the flash charging failed, Page: D, Address: 67, Data: 04 are written.
After repair, be sure to write Page: D, Address: 67, Data: 00.
[Power supplying Method]
Use the AC power adaptor (AC-L10A) when supplying the power to this set.
*1