5-24
MVC-FD100/FD100H/FD200/FD200H
8.
Mixed Color Cancel Adjustment
RadarW
RadarW
RadarW
To perform mixed color cancel adjustment based on data of each
color in color bar.
Mode
CAMERA
Subject
Color bar chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of page: F,
address :A0 (Note 2)
Measurering Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
A0 to A3
Specified Value
Check data : Except 3. (Note 2)
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
Displayed data of page: F, address: A0 of the adjusting
remote commander.
F:XX:A0
Check data
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-16)
2
Perform “Picture Frame
setting”.
(Refer to page 5-17)
3
6
01
D7
Press PAUSE button.
4
6
01
D5
Press PAUSE button.
(Note 3)
5
6
02
Check the data changes to
“01”.
6
F
A0
Check that the check data
satisfies the specified value.
(Note 2)
Note 3:
The adjustment data will be automatically input to page:
F, address: A0 and A3.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 1.
(Refer to page 5-16)
3
0
01
00
9.
Auto White Balance Standard Data Input
Adjust the white balance standard data at 3200K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
3A to 3D, 59
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
“Auto White Balance Standard Data Input” is available
only once after the power is turned on. Turn the power
off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-16)
2
Perform “Picture Frame
setting”.
(Refer to page 5-17)
3
6
01
11
Press PAUSE button.
4
6
01
0B
Press PAUSE button.
(Note 3)
5
6
02
Check the data changes to
“01”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 3A to 3D and 59.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 1.
(Refer to page 5-16)