5-23
MVC-FD100/FD100H/FD200/FD200H
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
2
6
01
00
Press PAUSE button.
3
Release the data setting
performed at step 1.
(Refer to page 5-16)
7.
Light Value Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the standard LV value.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of page: 1 (Note
2) and page: F, address: 28
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
26 to 28
Specified Value
FD100 (Note 3):
TYPE PA:
AE level 1: 0FE0 to 1020
AE level 2: 20 to 60
TYPE SO:
AE level 1: 0FE0 to 1020
AE level 2: 28 to 48
FD200:
AE level 1: 0FE0 to 1020
AE level 2: 30 to 50
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Note 3:
Type of CCD imager is different according to the CD
board in MVC-FD100.
Refer to page 7 to discriminate the type of CCD.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-16)
2
Perform “Picture Frame
setting”.
(Refer to page 5-17)
3
6
01
0D
Press PAUSE button.
(Note 4)
4
6
02
Check the data changes to
“01”.
5
0
03
06
6
1
Check that the displayed data
(Note 2) satisfies the AE
level 1 specified value.
7
F
28
Check that the displayed data
satisfies the AE level 2
specified value.
Note 4:
The adjustment data will be automatically input to page:
F, address: 26 to 28.