5-8
MVC-FD100/FD100H/FD200/FD200H
1-2.
INITIALIZATION OF B, D, E, F, 7, 9 PAGE DATA
1-2-1.
Initialization of D Page Data
1.
Initializing D Page Data
Note:
If the D page data has been initialized, the following
adjustments need to be performed again.
1) Modification of D page data
2) LCD system adjustments
Adjusting page
D
Adjusting Address
10 to EF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
2
2
03
→
00 (FD100), 01 (FD200)
3
2
00
2D
4
2
01
2D
Press PAUSE button.
5
2
02
Check the data changes to “01”.
6
2
FF
Check the data “01”.
7
Perform “Modification of D
page Data”.
2.
Modification of D Page Data
If the D page data has been initialized, change the data of the “Fixed
data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camcorder may not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of D Page Data:
Order Page Address Data
Procedure
1
2
00
29
2
2
01
29
Press PAUSE button.