5-33
MVC-FD100/FD100H/FD200/FD200H
18. CCD Linearity Check
RadarW
RadarW
RadarW
RadarW
RadarW
Check that CCD output keeps being straight even ISO sensitivity
is changed.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of Page: 1 (Note 1)
Measuring Instrument
Adjusting remote commander
Specified Value
FD100 (Note 2):
TYPE PA:
R ratio: 3D00 to 4300
B ratio: 3D00 to 4300
TYPE SO:
R ratio: 3900 to 4700
B ratio: 3900 to 4700
FD200:
R ratio: 3D00 to 4300
B ratio: 3D00 to 4300
Note 1:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Note 2:
Type of CCD imager is different according to the CD
board in MVC-FD100.
Refer to page 7 to discriminate the type of CCD.
Checking method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-16)
2
Perform “Picture Frame
setting”.
(Refer to page 5-17)
3
6
01
0F
Press PAUSE button.
4
6
14
Note down the data.
5
6
14
8B
6
0
03
04
7
1
Check that the displayed data
(Note 1) satisfied the R ratio
specified value.
8
0
03
05
9
1
Check that the displayed data
(Note 1) satisfied the B ratio
specified value.
10
6
14
90
11
6
12
Note down the data.
12
6
12
Set the following data, and
press PAUSE button.
FD100: 9E
FD200: 9D
13
Wait for 1 second.
14
0
03
04
15
1
Check that the displayed data
(Note 1) satisfied the R ratio
specified value.
16
0
03
05
Order Page Address Data
Procedure
17
1
Check that the displayed data
(Note 1) satisfied the B ratio
specified value.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
12
Set data noted down step 11,
and press PAUSE button.
3
6
14
Set data noted down step 4,
and press PAUSE button.
4
0
03
00
5
Release the data setting
performed at step 1.
(Refer to page 5-16)