2-15
DMW-S01NL/S02NL/ST001
(4) Disconnect the two power supply cables from the
MTS-11 board.
(5) Disconnect the five coaxial cables, one connector
cable and one USB cable.
In case of DMW-S02NL, disconnect the AUD cable
and HDVD cable to add to above the cables.
(6) Remove the one screw (PWH3
x
5) and remove the
MPU holder.
PWH3
x
5
Power cable
Coaxial cable
MPU holder
AUD cable
(DMW-S02NL only)
Connector cable
USB
cable
Power
cable
HDVD cable
(DMW-S02NL only)
MTS-11 board
MPU-120 board
CN2601
CN2001
CN2
CN3001
CN3201
CN502
CN2701
CN501
CP2402
CN103
CN13
CP2402(20P)
CP2401
MPU-120 board
When connecting the AUD cable, be sure
to connect the cable to outside of a board.
*
*
2-1. Digital media workstation/A/V block
(7) Remove the one screw (PWH3
x
5), open the two
levers on both sides of the board shown in arrow
direction (
1
) on the figure and pull out the MPU-120
board from the guide rail shown in arrow direction
(
2
) on the figure.
PWH3
x
5
MPU-120 board
1
2
m
.
When reconnecting the coaxial cables, be sure to inset
strongly.
.
After replacing the MPU-120 board, be sure to perform
the operation check, then perform the reassembling of
each parts.
Coaxial cable connections
Panel indication
MPU-120 board
Color
SDI IN
CN2001, SDI IN
Black
SDI OUT
CN3001, PGM OUT
Red
SYSTEM I/F IN
CN2701, FRM PC
Orange
SYSTEM I/F OUT
CN2601, TO PC
Yellow
MON OUT
CN3201, MON OUT 1
Green
Adjustment after replacement of the MPU-120 board
After replacing the MPU-120 board, be sure to downloading the
firmware that version is conformed to the application software,
to the Flash memory (IC2). Refer to Sec. 5-3-3 for confirmation
of the existing version No. and version up procedure of the
firmware. Also, confirm the configuration data that is downloaded
to the PLD IC2301, is conformed to the application software
version No. Refer to Sec. 7-8 for version up procedure of this
data. It also should be performed the every electrical alignment
items of this board by referring to Sec. 7, Electrical Alignment.
*
When DMW-IF02 is installed in DMW-S01NL.