1-51
DMW-S01NL/S02NL/ST001
1-10-2. Setup after installing
1.
Clear the hardware configuration information.
(Refer to Sec. 5-1-4. 2. Advanced)
1
Turn on the power of the unit.
2
When the “SONY” logo appears on the screen,
press the <F2> key.
3
Wait until BIOS setting screen is displayed.
4
Select the “Advanced” menu using arrow key
<
→
>.
5
Select “Advanced” at most top item from the
“Advanced” menu, press the <Enter> key.
6
Select “Reset Configuration Data” at second top
item from the “Advanced” menu, press the
<Enter> key.
7
As default setting is “No”, so press the <Enter>
key to set “Yes”.
8
After setting, select “Save & Exit” (<F10>), press
the <Enter> key.
2.
Install the application and driver.
3.
Perform the operating confirmation using self diagnos-
tics functions of the IF02 Assy (DMW-IF02) utility.
(Refer to Sec. 5-7-4)
4.
Connect the Fibre channel storage unit DMW-ST001
to the unit, perform the disk reconfiguration.
(Refer to Sec. 5-6-5)
n
When reconfiguring, all created data file has been cleared
on the DMW-S01NL.
1-10. Installation of DMW-IF02
AUD cable
HDVD cable
USB cable
HDVD cable
Cable clamp
AC wire clip
21. Check that each connectors are connected securely.
22. Set around each cables as shown in below figure.
23. Install the card stopper.
24. Install the PCI duct.
25. Install and fix the AV I/O block to the unit.
n
When installing, be careful not to catch the each
cables.