2-11
DMW-S01NL/S02NL/ST001
i)
Confirmation of disk configuration.
(Refer to “Sec. 5-6-4, 1”.)
.
Confirm the disk configuration is defined before replace-
ment of the board.
.
When the disk configuration is not displayed correctly,
confirm whether FC cable is connected properly and the
power of the disk unit is turned on.
ii) Confirmation of board information.
(Refer to “Sec. 5-6-5, 3,(1) step a)”.)
.
Perform the confirmation of each ID and each revision.
.
When the revisions of the firmware, RTOS and driver
are not expected, reinstall the disk utility.
(Refer to “Sec. 5-6-5, 3, (3) Install program”.)
As for revisions of each software, refer to Readme.txt
file that are recorded to CD-ROM for installation.
iii) Confirmation of FC port setting.
(Refer to “Sec. 5-6-5, 3, (1) step b)”.)
.
Confirm the number of the port and node names matches
one indicated in the board data supplied from the
manufacturer.
.
Confirm the port and node names are correct indicated in
the board data supplied from the manufacturer.
iv) Comparison test. (Refer to “Sec. 5-6-7, 1”.)
.
Run the following comparison test, confirm the no error
is found.
1
Select a specified drive for the disk unit.
2
Set “2048” of the I/O A.
3
Check “Compare” of the R/W.
4
Select “SysMer” of the “Memory Allocation”.
5
Input a log file name.
6
Click “Test Start” button. After the test ends, confirm
the message “Test is Completed !” is displayed on the
window.
7
Press “Open Log File” button to open the inputting log
file.
8
Confirm the “CompErr = 0” of result-A in log con-
tents.