5-11
DCR-TRV40/TRV40E/TRV50/TRV50E
1-2-2.
INITIALIZATION OF B, 1B PAGE DATA
Note:
When reading or writing the B page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 1B page data, select page: 0, address:
10, and set data: 01, then select B page. The 1B page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the B, 1B Page Data
Note1: If “Initializing the B, 1B Page Data” is performed, all data
of the B page and 1B page will be initialized. (It is
impossible to initialize a single page.)
Note2:
If the B, 1B page data has been initialized, the following
adjustments need to be performed again.
1) Modification of B, 1B page data
Note3:
The power supply voltage must be 6.0
±
0.1Vdc.
Adjusting page
B
Adjusting Address
00 to FF
Adjusting page
1B
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
5
02
FF
Set the data.
4
5
01
F3
Set the data, and press PAUSE
button.
5
5
00
01
Set the data, and press PAUSE
button.
6
5
02
Check that the data changes to
“00”.
7
2
00
29
Set the data.
8
2
01
29
Set the data, and press PAUSE
button.
9
Perform “Modification of B, 1B
Page Data” and “Loader writing
inhibit mode setting.”
2. Modification of B, 1B Page Data
If the B, 1B page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the B page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 1B page data, select page: 0, address: 10,
and set data: 01.
After completing the modification of 1B page data, reset the
data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of B, 1B Page data:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
3. Loader Writing Inhibit Mode Setting
Setting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
5
0E
00
Set the data, and press PAUSE
button.
4
5
03
20
Set the data, and press PAUSE
button.
5
5
01
FA
Set the data, and press PAUSE
button.
6
5
00
01
Set the data, and press PAUSE
button.
7
5
0E
Check that the data is “01”.
8
2
00
29
Set the data
9
2
01
29
Set the data, and press PAUSE
button.
4. Writing the Network Default Setting Value
(DCR-TRV50/TRV50E)
Switch setting: NETWORK .................................................... OFF
Writing method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
5
01
E7
Set the data, and press PAUSE
button.
4
5
09
80
Set the data, and press PAUSE
button.
5
5
0A
Set the following data, and press
PAUSE button.
03: US model
04: Europe model
01: Others model
6
5
00
01
Set the data, and press PAUSE
button.
7
5
0E
Check that the data is “01”.
8
0
01
00
Set the data.