— 2 —
SECTION 1 SERVICE NOTE
1-2. SELF-DIAGNOSIS FUNCTION
4. SELF-DIAGNOSIS CODE TABLE (page 1-4)
C
E
E
Block
Function
0
4
6
2
9
1
Detailed
Code
0
0
0
1
0
1
Symptom/State
Non-standard battery is used.
Steadyshot function does not work well.
(With yaw angular velocity sensor output
stopped.)
Abnormality when the power supply
capacitor of the flash unit is being
charged.
Self-diagnosis Code
Repaired b
y
:
Correction
Use the info LITHIUM battery.
Inspect yaw angular velocity sensor (SE5352 of JK-219 board)
peripheral circuits.
Checking or replacement of the flash unit. (
Note
)
Note:
After checking or replacement of the flash unit, perform the initialization of the unit. (Refer to “1-1-2. Preparations” of “5-1. CAMERA SECTION
ADJUSTMENT”.)
: Added portion
SECTION 4
PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS
4-3. PRINTED WIRING BOARDS
MA-408 BOARD (page 4-80)
12