2-18
DCR-TRV40/TRV40E/TRV50/TRV50E
VC-283
DD-176
1
16
1
16
VC-283 board
JK-219 board
MA-408 board
Adjustment remote
commander (RM-95)
AC power
adaptor
AC IN
CPC-7 jig
(J-6082-382-A)
Mechanism deck
Cabinet (L) section
DD-176 board
Extension cord (100P)
(J-6082-413-A)
To eject the cassette, connect the Cabinet (L)
section to the CN1007 on the VC-283 board.
Battery terminal board
(6P)
[SERVICE POSITION TO CHECK THE VTR SECTION]
Connection to Check the VTR Section
To check the VTR section, set the VTR to the “Forced VTR power ON” mode.
Operate the VTR functions using the adjustment remote commander (with the HOLD switch set in the OFF position).
Setting the “Forced VTR Power ON” mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 00.
3) Select page: D, address: 10, set data: 02, and
press the PAUSE button of the adjustment remote
commander.
Exiting the “Forced VTR Power ON” mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 00.
3) Select page: D, address: 10, set data: 00, and press
the PAUSE button of the adjustment remote commander.
4) Select page: 0, address: 01, and set data: 00.