2-11
DCR-TRV40/TRV40E/TRV50/TRV50E
2-12.EVF SECTION
2-13.FLASH UNIT (FLASH SECTION) (1)
VC-283
DD-176
1
Two tapping screws
(M1.7
×
5)
4
EVF section
2
FP-458 flexible board
(21P)
3
Remove the EVF section
from the groove.
2
Two screws (M1.7
×
4),
lock ace, p2
3
Remove the Grip cover
in the direction of the arrow.
1
Open the cassette lid
4
Turn over the insulating sheet
5
Flash unit
Shorting jig
(1k
Ω
/ 1w)
Power supply
capacitor
6
Remove the flexible board (45P)
from the CN4607.
The power supply capacitor of the Flash unit is
charged to the voltage as high as 300 V at a
maximum. The high voltage is not discharged
even after the main power of the machine is
simply turned off and the charged potential still
remains.
Discharge the residual voltage by referring to
Service Note (page 1-2).
Caution
Caution