15. Mechanical Shutter Adjustment
Adjustment Page
F
Adjustment Address
76 to 8B
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Input the following data to page: F, addresses: 76 to 8B.
Note:
Press the PAUSE button of the adjustment remote commander each
time to set the data.
3) Select page: 0, address: 01, and set data: 00.
16. Black Defective CCD Adjustment
Detect the black defective positions of the CCD imager.
Subject
Clear chart (All white)
(Approx. 40cm from the front of the lens)
Adjustment Page
1E (Note1)
Adjustment Address
20 to 2F
Note1:
When reading or writing the 1E page data, select page: 0, address:
10, and set data: 01, then select E page. The 1E page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note3:
This adjustment should be carried out upon completion of “Flange
Back Adjustment”.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
2C
01
Set the data.
4
6
9C
01
Set the data.
5
6
90
C0
Set the data.
6
6
91
01
Set the data.
7
6
92
00
Set the data.
8
6
93
01
Set the data.
9
6
01
79
Set the data, and press PAUSE
button.
10
Adjust the direction of the
camera so that the whole of the
screen is white.
11
6
01
8D
Set the data, and press PAUSE
button.
12
6
02
Check that the data changes to
“01”. (Note4)
Note4:
The adjustment data will be automatically input to page: 1E,
address: 20 to 2F
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
6
2C
00
Set the data.
4
6
9C
00
Set the data.
5
6
90
00
Set the data.
6
6
91
00
Set the data.
7
6
93
00
Set the data.
8
0
01
00
Set the data.
Address
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
87
88
89
8A
8B
NTSC
59
87
43
94
38
81
2F
7B
27
70
47
52
50
48
3B
1D
80
85
83
85
87
80
PAL
49
9D
37
76
2E
75
27
8D
20
76
47
52
4E
47
39
1E
7C
81
84
85
8B
7C
Data