5-9
DCR-TRV40/TRV40E/TRV50/TRV50E
1-2-1.
INITIALIZATION OF A, D PAGE DATA
Note:
The data of page: 0, address: 10 must be “00”.
1. Initializing the A, D Page Data
Note1:
If the A, D page data has been initialized, the following adjustments
need to be performed again.
1) Modification of A, D page data
2) Touch panel adjustment
Note2:
The power supply voltage must be 6.0
±
0.1Vdc.
Note3:
NTSC model: DCR-TRV40/TRV50
PAL model: DCR-TRV40E/TRV50E
Adjusting page
A
Adjusting Address
10 to D3
Adjusting page
D
Adjusting Address
10 to 67
Initializing Method of the A page:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
7
03
Set the following data.
05 (NTSC), 85 (PAL)
4
7
00
20
Set the data.
5
7
01
20
Set the data, and press PAUSE
button.
6
7
02
Check that the data changes to
“01”
7
2
00
29
Set the data.
8
2
01
29
Set the data, and press PAUSE
button.
9
Perform “Modification of A, D
Page Data”.
Initializing Method of the D page:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
7
00
22
Set the data.
4
7
01
22
Set the data, and press PAUSE
button.
5
7
02
Check that the data changes to
“01”
6
2
00
29
Set the data.
7
2
01
29
Set the data, and press PAUSE
button.
8
Perform “Modification of A, D
Page Data”.
2. Modification of A, D Page Data
If the A, D page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of A, D Page data
Order Page Address Data
Procedure
1
2
00
29
Set the data.
2
2
01
29
Set the data, and press PAUSE
button.
Note:
If the following symptoms occur after completing of the
“Modification of A, D page data”, check that the data of the “Fixed
data-2” addresses of A and D page are same as those of the same
model of the same destination.
1) The self-diagnosis code “E:20:00” on the LCD screen is displayed.
2) The power is shut off so that unit cannot operate.
3. A Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the A, D
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, D
Page Data”).
Address
Remark
Initial value
Initial value
NTSC PAL
00 to 0F
10 to 16
17
18
19 to 2E
2F
30 to 41
42
43 to 51
52
53
54
55
56
57 to 61
62
63
64 to 8F
90
91
92
93
D8
26
E3
1A
DA
24
D3
25
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Touch panel adj.