5-47
DCR-TRV40/TRV40E/TRV50/TRV50E
3-1-3.
Adjusting Connectors
Some of the adjusting points of the video section are concentrated
at VC-283 board CN1012. Connect the measuring instruments via
the CPC-7 jig (J-6082-382-A). The following table lists the pin
numbers and signal names of CN1012.
Table. 5-3-1.
3-1-4.
Connecting the Equipment
Connect the measuring instruments as shown in Fig. 5-3-2., and
perform the adjustments.
Pin No.
1
2
3
4
5
6
7
8
Signal Name
N. C.
RF MON
RF IN/LANC JACK IN
SWP
PANEL COM
GND
H START
GND
Pin No.
9
10
11
12
13
14
15
16
Signal Name
PANEL VG
GND
EVF VCO
GND
EVF VG
EXT DA
LANC SIG
N. C.
Remove the CPC lid.
CN1012
16
1
Fig. 5-3-1.
Adjustment
remote
commander
LANC jack
Main unit
AUDIO/VIDEO jack
TV monitor
VIDEO
(Yellow)
AUDIO L (White)
AUDIO R (Red)
Fig. 5-3-2.