7
Chapter 7 Location and Function of Parts and Controls
BVP-E10 Series Product Information Manual
94
illuminated until the adjustments are completed. If you
press this button while it is illuminated, or press the
START/BREAK button, the automatic adjustment is
canceled and the button flashes. To stop it flashing,
press the button again.
Note
If an error occurs during adjustment, the selected
button flashes.
c
c
c
c
BLACK (black balance) button
Press to automatically adjust the black balance and
black set. The button is illuminated during adjustment
and remains illuminated until the adjustments are
completed. If you press this button while it is
illuminated, or press the START/BREAK button, the
automatic adjustment is canceled and the button
flashes. To stop it flashing, press the button again.
Note
If an error occurs during adjustment, the pressed
button flashes.
d
d
d
d
CALL button
Press to send a call signal to the camera,. The tally
lamps on the camera and the red tally lamp on the
CCU-700/A700AP are illuminated(or are turned off if
they were already illuminated). When the CALL button
on the camera is pressed, the CALL button on this
panel illuminates and a buzzer sounds.
e
e
e
e
WHITE (white balance manual adjustment)
knobs
Used to manually adjust the white balance. Adjust the
Red and Blue signals, respectively.
f
f
f
f
BLACK (black balance manual adjustment)
knobs
Used to manually adjust the black balance. Adjust the
Red and Blue signals, respectively.
g
g
g
g
EXT (lens extender) indicator
Illuminates when the lens extender is in use.
h
h
h
h
IRIS/MB ACTIVE (iris/master black active)
button
Press and illuminate this button to enable the iris/
master black control block of the panel. When the
PANEL ACTIVE button is pressed, this block is
automatically selected as active.
i
i
i
i
SENS (sensitivity) control knob
Used for manual iris adjustment. See the table 'Iris
adjustment functions'.
j
j
j
j
COARSE control knob
Used for manual iris adjustment. See the table 'Iris
adjustment functions'.
k
k
k
k
ALARM indicator
Illuminates when the self-diagnostic function identifies
a problem in the camera or CCU system
l
l
l
l
AUTO button
Press and illuminate the button and the iris
automatically adjusts according to the subject
brightness. If you press the button when it is
illuminated, the illumination is turned off and manual
iris adjustment is enabled.
m
m
m
m
Camera number/tally indication window
(incorporated with MASTER/SLAVE indications)
The number of the camera being controlled from this
panel is displayed in orange. When a red tally signal is
sent to the camera, its number is displayed in black
against a red background. When a green tally signal is
sent to the camera, the number is displayed in black
against a green background. When the red and green
tally signals are sent simultaneously, the left half of the
background is illuminated red and the right half
illuminated green. In Master/Slave mode, to adjust the
white balance of multiple cameras the upper-left
(MASTER) corner is illuminated orange when the
camera being controlled from this panel is designated
as the master unit, and the upper-right (SLAVE) corner
is illuminated orange when designated as a slave unit.
RCP-700-exclusive features
n
n
n
n
Master black control ring
Turn to manually adjust the master black.
o
o
o
o
IRIS control lever/preview switch
When the AUTO button is not illuminated, you can
adjust the iris manually by moving this lever. When the
AUTO button is illuminated, the reference value for
automatic iris adjustment can be set in a range of +/-1f
stop with this lever. Push it axially to connect the key
signal for preview at the PREVIEW connector. See the
table "Iris adjustment functions."
RCP-701-exclusive features
p
p
p
p
MASTER BLACK control
Turn to manually adjust the master black.
q
q
q
q
IRIS control
When the AUTO button is not illuminated, you can
adjust the iris manually by turning the control. When
the AUTO button is illuminated, the reference value for
automatic iris adjustment can be set in a range of +/-1f
stop with this control. See the table 'Iris adjustment
functions'.
r
r
r
r
Iris marker
The white line on the marker provides a click position
for the IRIS control. Turn the gauge to set the line to the
most frequently used iris position, and it can be used
as the reference for manual iris adjustment. The
marker rotates infinitely in either direction. When no
click position is required, set the line outside the
rotation range of the IRIS control.
s
s
s
s
PREVIEW button
Connects the preview signal to the PREVIEW
connector to control an external monitor switcher.
Iris adjustment functions
IRIS lever (RCP-700)
IRIS control (RCP-701)
Adjust the iris within the varia-
ble controls.
COARSE control
Sets the lower limit for
CLOSED.
SENS control
Sets the upper limit for OPEN
according to the CLOSED
value set by the COARSE
control.
Summary of Contents for BVP-E10 Series
Page 1: ...Studio OB EFP Camera Family BVP E10 Series Product Information Manual ...
Page 8: ......
Page 16: ......
Page 17: ...BVP E10 Series Product Information Manual 1 2 A Total System ...
Page 40: ......
Page 41: ...BVP E10 Series Product Information Manual 1 4 Control System ...
Page 51: ...BVP E10 Series Product Information Manual 1 5 Optical Fibre Transmission System ...
Page 54: ......
Page 55: ...BVP E10 Series Product Information Manual 1 6 A Quick Lesson on Camera Settings ...
Page 57: ...BVP E10 Series Product Information Manual 1 7 Location and Function of Parts and Controls ...
Page 119: ...BVP E10 Series Product Information Manual 1 8 Menu Settings ...
Page 134: ......
Page 135: ...BVP E10 Series Product Information Manual 1 9 Connector Pin Assignment ...
Page 164: ......
Page 165: ...BVP E10 Series Product Information Manual 1 10 Glossary Terms and Definitions ...
Page 171: ...BVP E10 Series Product Information Manual 1 11 Specifications ...
Page 190: ......
Page 191: ...BVP E10 Series Product Information Manual 1 Appendix ...
Page 203: ......
Page 204: ......