Electrical connection
6
6.8.2 Connecting earthing conductor
Figure 49: Earthing wire between extension
cabinet and cover
1
Cover
2
Extension cabinet
3
Earth bolt
4
Contact disc
5, 7
Washer
6
Cable lug
8
Locking nut
9
Earth conductor
One earthing conductor (9) is
connected to the optional extension
cabinet.
►
Connect the other end of the
earthing conductor to the earth bolt
(3). Take care of the positioning of the
components (4) to (8).
►
Tighten the locking nut (8) with a
torque of 5 Nm.
6.8.3 Mounting cover
Figure 50: Mounting the cover of the
extension cabinet
►
Hook the cover into the front of the
extension cabinet.
►
Mount the cover with the three
screws. Tighten the screws only slightly,
making sure that the cover can still be
moved.
►
Close the door of the main cabinet
and align the cover.
►
Fully tighten the screws.
KD-291 | Part no. 52187 | EN | X01
page 53 of 63
3
4
5
6
7
8
9
1
2
Heruntergeladen von
Handbücher-Suchmachiene