4
Transport and storage
4.2.4 Temperature adjustment after transport
Damage to the storage system due to condensation
If the temperature of the storage system is lower than the ambient temperature
of the room when it is delivered, condensation may form inside the storage
system. This may damage the storage system.
►
Check the inside of the storage system for condensation before installation.
►
Only install the storage system if there is no condensation on the surfaces.
If the storage system has been transported in sub-zero temperatures,
proceed as follows:
1. Set up the storage system in a suitable location.
2. Open all control cabinet doors.
3. Leave the storage system to stand for at least 24 hours with open control
cabinet doors.
4. Only then can you commission the storage system.
page 18 of 63
KD-291 | Part no. 52187 | EN | X01
CAUTION