Redbox RB-PD2 User Handbook
91
SY
NCHR
ONISERS, DEL
A
Y
S & SILENCE DE
TEC
TORS - RB
-PD2
SYNCHRONISERS, DELAYS &
SILENCE DETECTORS
8
Serial Port Control
The Serial Port allows the RB-PD2 to be controlled and updated from a PC using the Sonifex
Serial Control Interface (SCI) software. This software is available as a free download from the
Sonifex website at www.sonifex.co.uk/sci.
Default Settings for the Serial Port
Baud Rate:
19200
Data Bits:
8
Stop Bits:
1
Parity:
Even
Handshaking:
None
Serial Interface Commands and Responses
Most of the commands follow the same structure: a 3 letter command followed by a colon,
followed by a parameter (if any) and terminated by Carriage Return with optional Line
Feed. A Line Feed character may be sent but it will be ignored by the RB-PD2. Commands
are not case sensitive.
Responses will be CR & LF terminated.
After the profanity delay has been powered-up, an initialisation string is sent
“Initialising PD2”.
Following are the commands and the expected responses:
Command
Description
Response
Bnn:
**Set baud rate where:
ACK: or NAK: (at old rate)
nn = 11 (115200 baud)
nn = 57 (57600 baud)
nn = 38 (38400 baud)
nn = 19 (19200 baud)
nn = 96 (9600 baud)
BPD:
Bypass disable
ACK: or NAK:
BPE:
Bypass enable
ACK: or NAK:
BSV:
**Bootstrap version request
BSV:Vn.n
where n.n = bootstrap version
CST:
Cough start
ACK: or NAK:
CSP:
Cough stop
ACK: or NAK: