Redbox RB-PD2 User Handbook
89
SY
NCHR
ONISERS, DEL
A
Y
S & SILENCE DE
TEC
TORS - RB
-PD2
SYNCHRONISERS, DELAYS &
SILENCE DETECTORS
8
START
RECORDING
MUTE OUTPUTS (both analogue and digital) and
ACTIVATE BYPASS
DELAY TO OUTPUT.
The options for remote input 7 and 8 remain unchanged.
If a remote input is set to “Delay To Output”, the corresponding remote output in the
remote output configuration options (Main Menu->Remotes->Configure Outputs-
>Output 1-6) is inaccessible and a message box is displayed stating that this remote
output is controlled by the corresponding input.
For remote inputs that are configured as “Delay To Output”, an active remote input
(shorted to 0V) produces an active open collector output on the corresponding remote
output after the current delay time period has elapsed. The open collector output is
de-activated after the current delay period when the remote input is de-activated.
Configure Outputs
This selection sets the remote output signaling options for the corresponding remote
output. From the REMOTES sub-menu select CONFIGURE OUTPUTS followed by the
required output number. Each remote output can signal when a certain function or state
has been activated. A list is shown displaying all the possible states that can be signaled
by the remote output, with the default being NO ACTION:
NO
ACTION
ZERO
DELAY
BUILDING
DELAY
DELAY SAFE (current delay is greater than safe period)
DELAY
OK
EXITING
DELAY
DUMP
ACTIVE
DROP
ACTIVE
COUGH
ACTIVE
RECORD
ACTIVE
OUTPUTS
MUTED
and
BYPASS ACTIVE.
CONTROL LOCK
This option allows the front panel bypass and rotary controls to be disabled. From the main
system menu select CONTROL LOCK. The available options are OFF and ON. Access to the
system menu is still enabled when the control lock is on to allow the lock to be removed.
When the control lock is enabled, a small key icon is displayed in the upper right side of the
main screen display. By default, the control lock is off.