OPERATING MANUAL PAT-800/805 version 1.09
54
f) dimensions ...................................................................................................... 330 x 235 x 120 mm
g) meter weight ......................................................PAT-800 approx. 4.05kg, PAT-805 approx. 4,75kg
h) storage temperature......................................................................................................
–20...+70
C
i)
operating temperature ....................................................................................................... 0...+40
C
j)
humidity ............................................................................................................................
20…80%
k) nominal temperature ..................................................................................................... +20...+25
C
l)
reference humidity ............................................................................................................
40…60%
m) display ...................................................................................................................... LCD, segment
n) memory of measurement results ....................................................................................... 990 cells
o) data transmission................................................................................................................ USB 2.0
p) quality standard .......................... development, design and manufacturing are ISO 9001 compliant
q) the product meets the EMC requirements acc. to ......... EN 61326-1:2009 and EN 61326-2-2:2006
Note:
During the measurement of PE continuity with PE 10/25 current the meter
may produce interference with values exceeding allowable limits defined in
EN 61326-1 and cause interference in other devices.
11.2 Standard equipment
Standard set of equipment supplied by the manufacturer includes:
power lead 1pc
–
WAPRZZAS1
test lead banana/banana, black 1.2m 1pc
–
WAPRZ1X2BLBB2X5
(
WAPRZ1X2BLBB
for PAT-
800)
black crocodile clip 1kV 1pc
–
WAKROBL30K03
(
WAKROBL20K01
for PAT-800)
1kV probe - black 1pc
–
WASONBLOGB3
USB cable
–
WAPRZUSB
fuse 0314 015.VXP 15A 250VAC 6.3x32mm Littlefuse 2 pcs
–
WAPOZB15PAT
cover
–
WAFUTL5
operating manual
11.3 Optional accessories
Additionally, the following items that are not included in the scope of standard equipment can be
purchased from the manufacturer or the distributors:
barcode stickers
PASS stickers (roll - 50 pieces of stickers)
FAIL stickers (roll - 50 pieces of stickers)
barcode stickers (roll - 100 stickers)
1.2 m double-wire lead (10/25A) U1/I1 1pc (PAT-805)
–
WAPRZ1X2DZBB1
1.2 m double-wire lead (10/25A) U2/I2 1pc (PAT-805)
–
WAPRZ1X2DZBB2
power probe Sonel 1pc (PAT-805)
–
WASONSPGB1
Kelvin crocodile clip 1pc (PAT-805)
–
WAKROKELK06
black crocodile clip 1kV 1pc
–
WAKROBL20K01
1kV probe -black 1pc
–
WASONBLOGB3
test lead banana/banana, black 1.2m 1pc
–
WAPRZ1X2BLBB
cable - adapter Shuko / IEC (for testing extensions)
–
WAADAPATIEC1
three phase socket adapter 16A*
–
WAADAPAT16P
three phase socket adapter 16A, switchable**
–
WAADAPAT16PR
three phase socket adapter 32A*
–
WAADAPAT32P
three phase socket adapter 32A, switchable**
–
WAADAPAT32PR
adapter for industrial sockets 16A***
–
WAADAPAT16F1