OPERATING MANUAL PAT-800/805 version 1.09
6
2 General description and features of the instrument
PAT-800 and PAT-805 digital meters are intended to measure the basic parameters of portable
electrical devices (power tools, household appliances, etc.) important for their safety: protective
conductor resistance, insulation resistance, continuity of connections, the leakage current.
The meter may be used to test the equipment, in accordance with the following standards:
EN 60745-1 Hand-held motor-operated electric tools. Safety. Part 1: General requirements.
EN 61029 Safety of transportable motor operated electric tools. General requirements.
EN 60335-1 Household and similar electrical appliances. Safety. Part 1: General requirements.
EN 60950 Information technology equipment
– Safety- Part 1: General requirements .
VDE 0404-
1 Prüf- und Messeinrichtungen zum Prüfen der elektrischen Sicherheit von
elektrischen Geräten. Teil 1: Allgemeine Anforderungen.
VDE 0404-
2 Prüf- und Messeinrichtungen zum Prüfen der elektrischen Sicherheit von
elektrischen Geräten. Teil 2: Prüfeinrichtungen für Prüfungen nach Instandsetzung, Änderung
oder für Wiederholungsprüfungen.
VDE
0701-0
702
Prüfung
nach
Instandsetzung,
Änderung
elektrischer
Geräte.
Wiederholungsprüfung elektrischer Geräte. Allgemeine Anforderungen für die elektrische
Sicherheit.
Basic functions of the instrument:
Measurement of network voltage and frequency
Checking the resistance of L-N circuit
Checking the fuse
Measurement of protective conductor resistance (Protection class - I):
technical measurement method
measurement with sinusoidal current of network frequency and values: 200mA, 10A (only
PAT-805) and 25A (only PAT-805)
adjustable measurement time
adjustable upper limit in the range of: 10mΩ …1.99Ω with resolution 0.01Ω
Measurement of insulation resistance:
three test voltages: 100V (only PAT-805), 250 (only PAT-805) and 500V
measurement of insulation resistance up to 600M
automatic discharge of the capacitance of tested object after the insulation resistance
measurement is completed
adjustable measurement time
adjustable lower limit within the range of 0.1 ….9.9 MΩ with resolution of 0,1MΩ
Measurement of substitute leakage current:
adjustable measurement time
adjustable upper limit in the range of: 0.01 ... 9.9 mA with resolution of 0.01mA/0.1mA
Measurement of PE leakage current
adjustable measurement time
adjustable upper limit in the range of: 0.01 ... 9.9 mA with resolution of 0.01mA/0.1mA
Measurement of differential leakage current:
adjustable measurement time
adjustable upper limit in the range of: 0.01 ... 9.9 mA with resolution of 0.01mA/0.1mA