Somogyi Home FKF2000/SLCD Instruction Manual Download Page 4

WALL MOUNTING AND SETUP procedure

1.

 

Before switching on for the first time, carefully remove the packaging material taking care not to damage 

the appliance and power cable. Do not use the product if it is damaged in any way!

2.

 

The device may only be used in dry indoor conditions!

3.

 

The free flow of warm air must be ensured for proper operation, therefore, please select the location for 

wall mounting according to Figure 2. Do not locate the appliance directly below a wall outlet!

4.

 

In order to insert the wall studs, drill holes with appropriate size into the wall, at least 200 cm from the 

floor, along a horizontal line and 420 mm from each other.

5.

 

Insert the studs into the holes then drive the enclosed screws into the studs so that the screw heads 

extend approx. 10 mm from the wall surface.

6.

 

Hang the unit's rear panel onto the screw heads at the holes, move it to the left then let it down, till stop. 

Make sure that the heater is hanging securely on the wall!

7.

 

Connect the unit's power cable into a standard grounded wall outlet!

8.

 

Insert 1 pc CR2025 (3

 

V) button cell to the remote controller! Take care of the right polarity! This 

completes the setup of the appliance.

Do not cover!

Covering the unit can cause overheating, fire or electric shock!

Caution:  Risk  of  electric  shock! 

Do  not  attempt  to  disassemble  or  modify  the  unit  or  its 

accessories. In case any part is damaged, immediately power off the unit and seek the assistance of 

a specialist.

In the event that the power cable should become damaged, it should only be replaced by the 

manufacturer, its service facility or similarly qualified personnel.

FEATURES

wall mounted PTC* fan heater for heating the air or indoor premises 

 adjustable power (1000 / 2000 W) 

 operating modes: warm and hot air 

 switchable swinging 

 built-in 

thermostat 

 overheating protection 

 8-hour timer 

 temperature display 

 touch buttons 

 with remote controller

STRUCTURE

 (Figure 1)

1.

 

cold air inlet 

• 

2.

 

main switch

 • 

3.

 

power cable

 • 

4.

 

mounting points

 • 

5.

 

warm air outlet 

• 

6.

 

swinging air blade 

• 

7.

 

screws, studs 

• 

8.

 

temperature display

 • 

9.

 

ON/OFF switch, heating 

stages touch button: 

ON/OFF Heat

 • 

10.

 

swing switch touch button: 

Swing

 • 

11.

 

timer switch touch button: 

Timer

 • 

12.

 

thermostat control touch button: 

Temperature

 • 

13.

 

heating 

stage

 • 

14.

 

swinging

 • 

15.

 

timer mode

 • 

16.

 

thermostat control

 • 

17.

 

on/off switch: 

ON/OFF

 • 

18.

 

timer setting: 

Timer

 • 

19.

 

temperature setting: 

Temperature

 • 

20.

 

heat level setting: 

Heat

 • 

21.

 

switch of swinging

:

 

Swing

OPERATION

The appliance can be operated with the touch buttons or with the remote controller. 

After you connected the unit to the power network, turn it on with the main switch (2). Then it will beep short, and the temperature display will show the current temperature in °C. 

 on the device: you can turn on the unit with 

ON/OFF

 

h

eat touch button, and it will start operation on low heating stage (1000 W, blue indicator icon (13)). After second push of button, 

the device will switch to higher heating stage (2000 W, green indicator icon (13)). After third push of the button, heating will switch off, the fan will work c.a. 20 seconds more, then the 

device will switch off.  

 by remote controller: you can turn on or off the unit with 

ON/OFF

 switch. You can switch between low or high heating stages with

 the

 

Heat

 button.

 on the device or by the remote controller: You can switch on the continuous swinging with the 

Swing

 button, and you can fix the air blades in the current position. With the 

Timer

 

button on the remote controller you can set the remaining operating time, in 1-hour increments up to 12 hours. You can select desired temperature with 

Temperature

 button 

(between 20 – 30 °C), which will be displayed by flashing digits. If 00 is selected by stepping the temperature, it means exit from the thermostat mode. The 

thermostat

 of the unit 

will switch on the actual heating stage, once the sensed temperature falls below the pre-set by 2 °C. 

Once it reaches the set temperature, the heater, the fan and swinging will 

turn off. 

After a power failure, when the power comes back, the unit switches to standby mode, all settings will be cleared, only temperature will be displayed, device will not heat. If you switch 

it off and after back with the remote control, it will operate on low heating stage, the previous settings are not stored.

In case of overheating, the 

overheating protection function

 will switch off the unit, for example, when the air inlets and outlets are covered. Power off the unit by unplugging it from 

the electric outlet. Allow the appliance to cool (for at least 30 minutes). Check whether the air inlets and outlets are obstructed or not, and clean them if necessary. Switch on the unit 

again. If the overheating protection activates again, power off the unit by unplugging it from the electric outlet and contact the service facility.

CLEANING, MAINTENANCE

In order to ensure optimum functioning, the unit may require cleaning at least once a month, depending on the manner of use and degree of contamination.

1.

 

Switch off and power off the unit by unplugging it from the electric outlet before cleaning. 

2.

 

Allow the appliance to cool (for at least 30 minutes).

3.

 

Use a vacuum cleaner with a brush attachment to clean the air inlet and outlet openings.

4.

 

Use a slightly moistened cloth to clean the unit's exterior. Do not use any aggressive cleaners. Avoid getting water inside the unit and on the electric components!

TROUBLESHOOTING

TECHNICAL DATA

power supply:. . . . . . . . . . . . 230

 

V / 50 Hz

output: . . . . . . . . . . . . . . . . . 1000 / 2000 W

maximum output: . . . . . . . . . 2000 W

IP protection: . . . . . . . . . . . . IP20: Not protected from ingress of water!

size of heater:. . . . . . . . . . . . 54 x 20 x 12 cm

weight:. . . . . . . . . . . . . . . . . 2,6 kg

length of power cable: . . . . . . 1,

5

5 m

noise level:. . . . . . . . . . . . . . 60 dB(A)

*  The  PTC  (Positive  Temperature  Coefficient)  is  a  ceramic 
polycrystalline semiconductor alloyed with barium and titanium. Its 
true advantage lies in that it is in possession of a temperature self-
regulation property so no precautions need to be taken against 
overheating,  in  addition  to  the  unit  being  significantly  energy 
efficient.

Malfunction

The unit does not heat in heating mode.

The overheating protection activates frequently.
The unit does not respond to the remote controller's signal.

Possible solution

Check the section on overheating protection!
Check the thermostat settings!
Clean the appliance!
Check the remote controller batteries.

Summary of Contents for Home FKF2000/SLCD

Page 1: ...de utilizare uputstvo za upotrebu uputstvo za upotrebu navodilo za uporabo navodilo za uporabo n vod k pou it n vod k pou it uputa za uporabu uputa za uporabu eredeti haszn lati utas t s n vod na pou...

Page 2: ...100 cm min 100 cm min 200 cm figure 1 Abbildung 1 1 bra 1 obraz figura 1 1 skica 1 skica 1 obr zek 1 slika figure 2 Abbildung 2 2 bra 2 obraz figura 2 2 skica 2 skica 2 obr zek 2 slika 1 3 4 2 5 6 7...

Page 3: ...urn the unit on because any covering or improper location of the unit can cause danger of fire 8 The appliance should be used as intended for heating air not for general heating purposes 9 The stream...

Page 4: ...heatingwillswitchoff thefanwillworkc a 20secondsmore thenthe devicewillswitchoff byremotecontroller youcanturnonorofftheunitwithON OFFswitch YoucanswitchbetweenloworhighheatingstageswiththeHeatbutton...

Page 5: ...n ll an bekapcsolhatj k a k sz l ket mert a k sz l k esetleges letakar sa helytelen elhelyez se t zvesz lyt okozhat 8 A k sz l k rendeltet se szerint csak a leveg felmeleg t s re haszn lhat ltal nos...

Page 6: ...2000 W z ld visszajelz ikon 13 A gomb harmadszori megnyom s ra a f t s kikapcsol a ventil torm gkb 20m sodpercigm k dik majdak sz l kkikapcsol t vir ny t n azON OFFgombbalki sbekapcsolhatjaak sz l ke...

Page 7: ...vzduchu nie na v eobecn ohrievanie 9 Otvor v vodu vzduchu nikdy nesmerujte priamo na z clony alebo in hor av l tky 10 Pri umiestnen dbajte na to aby ste pr stroj neumiestnili v bezprostrednejbl zkosti...

Page 8: ...na vy stupe ohrievania 2000 W zelen kontrolka 13 Tret m stla en m tla idla sa ohrievanie zastav ale ventil tor funguje e te 20sek nd potomsavypne nadia kovomovl da i pomocoutla idlaON OFFm eteza avypn...

Page 9: ...paratul n mod independent pentru c acoperirea sau pozi ionarea incorect pot crea risc de incendiu 8 Aparatul a fost proiectat doar pentru nc lzirea aerului i nu n scopuri generale de nc lzire 9 Nu dir...

Page 10: ...u ap sare a butonului aparatulvacomutapetreaptaurm toarede nc lzire 2000W semnalverde 13 Laatreiaap sareabutonului nc lzireasevaopri ventilatorulmaifunc ioneaz timpde cca 20desecunde dup careaparatuls...

Page 11: ...a se izazove po ar 8 Ure aj je predvi en isklju ivo za zagrevanje vazduha prostorija za druge svrhe ne 9 Vreo vazduh iz ure aja ne usmeravajtena zapaljive materijale kao to su zavese i sli no 10 Ne po...

Page 12: ...li plava ikonica 13 Drugim dodirom tastera aktivira e se je e grejanje 2000 W svetli zelena ikonica 13 Na tre i dodir tastera grejalica se isklju uje ali ventilator jo radi oko 20 sekundi da bi se ohl...

Page 13: ...e ne usmerjajte na vnetljive materijale kot so zavese in podobno 10 Ne postavljajte je blizu vnetljivih materijalov min 100 cm 11 Prepovedana je uporaba v prostorih kjer se nahajajo vnetljive teko ine...

Page 14: ...ca 13 Z drugim dotikom tipke se aktiviramo nej esegrevanje 2000W svetizelenaikonica 13 Natretjidotiktipkesegrelecizklju i aventilator edelujeokoli20sekund dabiseohladilanotranjostgrelca zdaljinskimupr...

Page 15: ...tepl vzduch nesm rujte bezprost edn na z clony nebo na jin ho lav materi ly 10 Neum s ujte do bl zkosti ho lav ch l tek vzd lenost min 100 cm 11 Je zak z no pou vat v takov m prost ed ve kter m se moh...

Page 16: ...upe vyt p n 2000 W zelen kontroln ikonka 13 Po t et m stisknut tla tka se funkce vyt p n vypne ventil tor v akbudeje t podobucca20vte infunk n potomsetopn t lesovypne d lkov movlada em topn t lesom et...

Page 17: ...o aji ure aja mogu uzrokovati opasnost od po ara 8 Ure aj bi trebao biti kori ten u skladu s namjenom za grijanje zraka a ne za op e namjene grijanja 9 Mlaz vru eg zraka ne bi trebao biti usmjeren ka...

Page 18: ...e zaustaviti samoventilator eraditijo 30sekundi dok eure ajbrojatiunazad Nakonisklju ivanjazra nilopatice esezatvoriti ure aj ebitiustanjumirovanja Mo ete uklju iti i isklju iti aparat sa on off tipka...

Page 19: ...suport m cheltuielile legate de acesteobliga ii NEUTRALIZAREABATERIILOR ACUMULATORILOR Bateriile acumulatorii nu pot fi gestiona i mpreun cu de eurile menajere Este datoria utilizatorului stipulat pr...

Page 20: ...ra de origine China Uvoznik za SRB ELEMENTA d o o Jovana Miki a 56 24000 Subotica Srbija Tel 381 0 24 686 270 www elementa rs Zemlja uvoza Ma arska Zemlja porekla Kina Proizvo a Somogyi Elektronic Kft...

Reviews: