ID
Option
Description
1
snow
(default)
Settings for snow applications are active. These settings include precipitation
detection and snowfall limits (see
and
). Rate of
change filtering (
RoC, max. without precip. (./h)
and
)
is active.
2
water
Settings for water application are active. Precipitation detection and rate of
change filtering (RoC) are deactivated.
3
others
Settings for water and snow applications are inactive. Used for generic
level/distance measurements. A constant rate of change filter (
) is active.
ATTENTION
By default the USH-9 is configured for snow-depth measurements.
If the instrument is used for water level monitoring, adapt its configuration as
described in
Configuring the USH-9 for water level measurements
11.6.6
Every level/distance measurement is stored internally in a buffer for filtering. This setting defines the
length of the time window of which the data are stored in the buffer. If the buffer is full, the oldest
value is replaced by the most recent one.
The figure below illustrates the default moving filter duration of 180 seconds. While a
of 90 seconds embraces two measurement values, an interval of 45 seconds includes 4 val-
ues.
11.6.7
The level/distance values in the buffer can be filtered by one of the following options:
1
1
C
o
n
fi
gu
ra
ti
o
n
o
f
th
e
U
SH
-9
56
Manual