Value range
Default
Units
1ˈ000…99ˈ999ˈ999
10'000
mm
D-H-C
View spectral distribution
generic-special-functions-view-spectral-distribution
With this command the sensor is set into spectral mode. After 30 minutes the spectral mode is
switched off automatically.
With the Commander software the spectra can be recorded, visualized and stored for expert analysis
of the sensor signal, e.g. additional reflections.
D-H-D Maximum standard deviation
ush-max-standard-deviation
At the beginning of each measurement the USH-9 fires an impulse to detect the approximate position
of the snow surface. Subsequent impulses then determine the exact snow depth. This setting spe-
cifies the maximum acceptable standard deviation of a complete measurement.
Value range
Default
Units
0…99ˈ999ˈ999
70
mm
D-H-E
Rate of change, maximum (./h)
ush-roc-max
Only applicable if
is set to
others
. Maximum permissible rate at which the level is allowed
to change.
Value range
Default
Units
0…99ˈ999ˈ999
30
mm/h
D-H-F
RoC, max. without precip. (./h)
ush-roc-max-without-precip
1
4
P