If a limit defined in
is reached, the status of IOUT2 is set to high and 20 mA is applied to
the output. This status is maintained until the specified hold time elapses. Setting this parameter sup-
presses a flickering signal if the monitored variable fluctuates around the limit value.
Value range
Default
Units
0…360
30 (default)
min
D-F-I
Simulate current output
generic-analog-out-simulate-current
With this function the analog outputs can be simulated. Upon submission of a current value between
4 and 20 mA the corresponding values of the selected variable are displayed. The selected current is
also applied to the analog outputs and can be read with a connected data logger or multimeter. By
pressing Return/Enter again the simulation stops.
NOTE
If
is deactivated, no current output can be simulated.
If
is set to
just during TRIG
, the trigger must be set prior to simulation.
Additionally, the trigger must be reset before each simulation.
D-G Status limits
D-G-A
D-G-B
D-G-C
D-G-D
D-G-E
D-G-A
Level limit
ush-level-limit
The level above which the status is set to high. This limit is used to report significant levels or snow
depths.
Value range
Default
Units
0…99ˈ999ˈ999
0
mm
1
4
P