22
Copyright © 2013 Somfy SAS. All rights reserved.
CUSTOMISING yOUR INSTALLATION
Default operation
Operating your gate in sequential mode and complete opening mode
Successive presses of the same remote control button will lead to the following movements of the gate:
Open, Stop, Close, Stop,
Open etc.
Total opening
by pressing button 1.
Close
by pressing the button 1 again.
Stop
when moving by pressing button 1
again.
Detecting obstacles
When closing the gate, if an obstacle is detected (abnormal force on the motorisation), the gate stops then reopens
When opening the gate, if an obstacle is detected (abnormal force on the motorisation), the gate stops.
STOP
STOP
STOP
Press button 1 on the remote control
twice.
> The
indicator light stays on to
indicate that automatic mode has been
activated.
3
Precautions for use
The automatic mode can only be activated if a set of photoelectric cells is installed (see wiring page 25).
The remote control must be placed on the control unit electronics to access the settings.
Access to the settings with a 3-button remote control is not possible.
2
3
1
x2
Place a memorised 2- or 4-button
remote control on the target.
Press button 1 on the remote control
until the
indicator light flashes.
1
Activating automatic closing mode
Press button 2 on the remote control
until the
indicator light goes out then
comes on continuously.
Release the button.
The
indicator light flashes.
2
Once step 1 has been carried
out, you can carry out the
following steps remotely
(without placing the remote
control on the target).
When using your gate in automatic mode, standard EN 12 453 requires a set of photoelectric cells to be installed (see wiring on
page 25).
Somfy recommends installing an orange light (see wiring on page 26) and area lighting (see wiring on page 26).
Automatic closing