9.2. Programming automatic closing
9.3.1. setting input 18
to have input 18 in oPEN only:
[1].
Disconnect the control unit.
[2].
Press the PROG, LAVORO and PAUSA buttons at the same time and then reconnect the control logic while keeping the
buttons pressed.
to switch input 18 back to PEdEstriaN oPEN/ClosE:
[1].
Disconnect the control unit.
[2].
Press the LAVORO and PAUSA buttons at the same time and then reconnect the control logic while keeping the buttons pressed.
9.3.2. setting input 19
to have input 19 in ClosE only:
[1].
Disconnect the control unit.
[2].
Press the PROG and PAUSA buttons at the same time and then reconnect the control logic while keeping the buttons
pressed.
to switch input 19 back to oPEN/ClosE:
[1].
Disconnect the control unit.
[2].
Press the PROG and LAVORO buttons at the same time and then reconnect the control logic while keeping the buttons pressed.
To programme automatic closing, use the PAUSA and PROG
buttons of the control unit.
To set the parameters for inputs 18 and 19, use the PAUSA,
LAVORO and PROG buttons of the control unit.
O
LAVOR
PROG
+
-
RE
G
10
9
18
19
20
21
22
START
PED
STOP
FOTO
FCA
FCC
COSTA
DL10
DL11
ENCODER
DL12
SW1
SW2
1
2
3
4
5
6
7
8
SOG/4
A
F1
F2
O
N
O
N
O
LAVOR
AA
PROG
+
-
R
EG
21
22
START
PED
STOP
FOTO
FCA
FCC
COSTA
DL10
DL11
EN
C
O
D
ER
DL12
SW
1
SW
2
2
SO
G
/4
A
F1
F2
O
N
O
N
1
3
4
5
8
6
7
9
10
19
20
18
PAUSA
PROG
PROG
+
-
RE
G
10
9
18
19
20
21
22
START
PED
STOP
FOTO
FCA
FCC
COSTA
DL10
DL11
ENCODER
DL12
SW1
SW2
1
2
3
4
5
6
7
8
SOG/4
A
F1
F2
O
N
O
N
PROG
+
-
R
EG
21
22
START
PED
STOP
FOTO
FCA
FCC
COSTA
DL10
DL11
EN
C
O
D
ER
DL12
SW
1
SW
2
2
SO
G
/4
A
F1
F2
O
N
O
N
1
3
4
5
8
6
7
9
10
19
20
18
PAUSA
PROG
O
LAVOR
DL10
PAUSA LAVORO PROG
[1]
[2]
DL10
PAUSA LAVORO PROG
DL10
PAUSA LAVORO PROG
DL10
PAUSA LAVORO PROG
DL10
PAUSA LAVORO PROG
[1]
[2]
DL10
PAUSA LAVORO PROG
[3]
DL10
PAUSA LAVORO PROG
DL10
PAUSA LAVORO PROG
DL10
PAUSA LAVORO PROG
...
9.2.1. activating automatic closing
(max timer 120s)
[1].
With the control unit powered and the gate closed (FCC LED
off), press the PROG button.
The DL 10 LED will flash to indicate that the control unit is in
programming mode.
[2].
Press and hold the PAUSA button until the contacts «click».
The indicator will come on.
The control unit will start counting the seconds (indicated by
the intermittent flashing of the indicator) for the automatic
gate closure delay.
[3].
Press the PAUSA button when the required time is reached.
The control logic will memorise the time elapsed between the
two presses of the PAUSA button.
The automatic closure delay of the gate is programmed.
Note: if the PAUSA button is not pressed a second time, the
control unit will automatically exit the programming mode after
120 seconds and store the maximum time of 120 seconds for the
automatic closing delay.
9.2.2. deactivating automatic closing
[1].
With the control unit powered and the gate closed (FCC LED
off), press the PROG button.
The DL 10 LED will flash to indicate that the control unit is in
programming mode.
[2].
Press and hold the PAUSA button until the DL10 LED goes out.
The control unit will exit the programming phase, automatic
closing is deactivated.
9.3. setting inputs 18 and 19