6.3.3. Assembly recommendations
For an opening up 150°, dimension B must be zero or negative.
If the pillar is not sufficiently wide, fit a strengthening bracket (see “3.2.
Pillar strengthening bracket”).
Min. 162 mm
90°
Min. 130°
Max. 150°
Dimension B
Dimension B
Dimension A
min. 250 mm
Min. 320 mm
min. 20 mm
min. 529 mm
885 mm
885 mm
Length L
Length L
Side room
A measurement of the force of impact aer the auto-programming pro-
cess must be taken to check compliance with the safety standards.
6.4. Special gate or pillar dimensions / opening up
to 120°
short
short
260 mm
420 mm
Motor arm
Gate arm
Medium
Medium
360 mm
620 mm
long
long
460 mm
820 mm
6.4.1. Field of application
800 1000 1200 1400 1600
1800 2000 2200 2400 2500
400
350
300
250
200
150
100
50
0
8
400
350
300
250
200
150
100
50
0
00 1000 1200 1400 1600
1800 2000 2200 2400 2500
OPENING < 90°
Length L in mm
Dimension B in mm
Dimension B in mm
Length L in mm
120° > OPENING > 90° MIN. A = 150 MM
Short motor
arm + short
gate arm
Min. C =
400 mm
Medium motor arm
+ short gate arm
Min. C =
650 mm
Medium motor arm +
medium gate arm
Min. C = 500 mm
Long motor arm + long gate arm
Min. C = 600 mm
Long motor arm + medium gate arm
Min. C = 800 mm
LOCK RECOMMENDED
LOCK RECOM-
MENDED
LOCK OBLIGA
TORY
LOCK OBLIGA-
TORY
12
Copyright© 2017 SOMFY ACTIVITES SA. All rights reserved.
Axovia Multipro
EN