4.5.6. Blocking the stops
12)
Block the stops using the bolt provided.
4.5.7. Locking the motor
13)
Place the gate leaves in the intermediate position.
14)
Lock the motors (padlock closed ).
4.6. Wiring the motors
1)
Insert the motor cable into the cable grommet.
2)
Consult the 3S Axovia control box instructions for the motor wiring in
the control cabinet.
5. COMMISSIONING
Refer to the installation guide for the 3S Axovia control box to commission
the installation.
6. INSTALLING SPECIAL ARMS
6.1. Jointed arm for opening outwards
Attention
The gate must not open onto a public thoroughfare.
The installation of a set of photoelectric cells is strongly recom-
mended.
)ROG WKH DQJOHV
VXFK WKDW WKH EROW
KHDGVDUHEORFNHG
0RWRUDUP
*DWHOHDIDUP
6.1.1. Field of application
Weight per gate leaf = max. 100 kg
800 1000 1200 1400 1600
1800 2000 2200 2400 2500
400
350
300
250
200
150
100
50
0
Length L in mm
Dimension B in mm
Jointed arm + long gate arm
Jointed arm +
medium gate arm
Jointed arm +
short gate arm
6.1.2. Assembly recommendations
Attention
The position of the arm must be identical to the diagram.
The motor connections must be reversed in relation to the standard
arm kits.
100 mm
90°
Dimension B
9
Copyright© 2017 SOMFY ACTIVITES SA. All rights reserved.