6.1.3. Position of the mounting plate
Attention
The motor must be placed as close as possible to the edge of the
pillar (dimension A = 0).
AM
AH
68 mm
A
A measurement of the force of impact aer the auto-programming pro-
cess must be taken to check compliance with the safety standards.
6.2. Ball-joint arm for opening on a slope of up to
20%
)ROG WKH DQJOHV
VXFK WKDW WKH EROW
KHDGVDUHEORFNHG
*DWHOHDIDUP
0RWRUDUP
6.2.1. Field of application
Weight per gate leaf = max. 100 kg
800 1000 1200 1400 1600
1800 2000 2200 2400 2500
400
350
300
250
200
150
100
50
0
Dimension B in mm
Length L in mm
LOCK RECOM-
MENDED
Medium motor arm
+ ball-joint arm
6.2.2. Assembly recommendations
min. 450 mm
90°
Dimension B
Length L
Side room
10
Copyright© 2017 SOMFY ACTIVITES SA. All rights reserved.
Axovia Multipro
EN