AROW Series
Data Diode
Installation and Operation
11-2
Physical
Dimensions
Length 360mm x Width 482mm x Height 44mm
NB the overall envelope required will be larger than this to
accommodate rear panel connections and bend radius requirement
for cables. Note also that sides should not be fully obstructed since
cooling vents are used.
Environmental
Temperature (Operating)
0°C to 50°C
Temperature (Storage)
-20°C to +85°C
Note: In common with all electronic equipment, allow suitable
stabilisation time when moving from extreme storage to operating
conditions before powering on the unit, especially where
condensation might be expected to form. DO NOT operate the unit if
condensation is present.
Relative Humidity (Operating)
5% to 95% non-condensing
Shock and Vibration
suitable for normal commercial transport when using the original
factory packaging
Power
Supply
Operating Voltage:
90V to 240 V
Operating Frequency:
49 to 61 Hz
Connector
Standard 3-pin IEC connector
Consumption
30VA Maximum
Summary of Contents for AROW Series
Page 2: ...AROW Series Data Diode Installation and Operation ...
Page 8: ...AROW Series Data Diode Installation and Operation 1 5 15 INDEX 15 1 ...
Page 18: ...AROW Series Data Diode Installation and Operation 4 3 ...
Page 69: ...AROW Series Data Diode Installation and Operation 11 4 This page intentionally blank ...