Preparation
These instructions should be followed before installation, and any
time the unit is moved, connections changed or re-installed.
Check the items received to ensure that they match your data
input/output configuration requirements.
No special tools are required. You will need a large flat headed
screwdriver.
In common with other electroonic equipment of this class,
AROW
needs to be installed in a controlled environment where the
temperature will not go above 40°C or below 0°C, and where the
relative humidity is between 15% and 55%, and is non-condensing.
Ensure that you allow the unit to stabilise in this environment before
use, especially if it has been subjected to transportation in low-
temperature or high-humidity environments
Check that the cables that you will be using to connect to the data
inputs and the control and data Ethernet ports are of correct length
and are well and correctly labelled. The cables should be tied into a
wiring loom for tidiness. Electrical Data cables should be a minimum
of Cat 5e for GBE operation, optical cables should be laser
compatible (yellow sheath), 9/125 terminated for LC connection.
Summary of Contents for AROW Series
Page 2: ...AROW Series Data Diode Installation and Operation ...
Page 8: ...AROW Series Data Diode Installation and Operation 1 5 15 INDEX 15 1 ...
Page 18: ...AROW Series Data Diode Installation and Operation 4 3 ...
Page 69: ...AROW Series Data Diode Installation and Operation 11 4 This page intentionally blank ...