AROW Series
Data Diode
Installation and Operation
5-1
5.
OPERATION
In this Section
I
NTRODUCTION
5-1
L
OW
S
IDE
5-2
H
IGH
S
IDE
5-3
UDP
OVER
SOCAT
5-3
UDP/M
ULTICAST
D
ATA
5-4
L
INUX
UDP
E
XAMPLE
:
5-5
F
ILE TRANSFER SOFTWARE
5-5
P
ERFORMANCE
C
HARACTERISATION
5-5
T
HROUGHPUT
5-5
B
UFFER OVERRUNS
(TCP
D
ATA
)
5-6
Introduction
Both high side (clean) and low side (dirty) AROW TCP socket servers
listen to connections on port 9876. UDP data can use any normally
permitted port, Multi-cast data is supported for any address in the normal
multi-cast range.
Redundant Version
For firmware version 1 revision 3 and later, a dual redundant backup
path is provided with automatic failover mechanisms.
All versions
Any data received on the low side socket is transferred over the internal
optical link to the high side.
Any data received from the optical link is sent on the high side socket.
There is no reverse data path. Data received on the high side socket will
be silently discarded. As the low side optical connections are not made,
no data will ever be sent from
AROW
out through a low side TCP socket.