56
Air model
– Alpes 10 kW
For the
Alpes 10 kW
free standing pellet fire model, remove the side covers to access
the side lids of the combustion chamber. To clean the interior of the unit, unscrew the
wing nuts (Figure 47) remove the lid and vacuum the ash (Figure 48-a). Using a 20-
25mm wide and 80cm long steel brush, clean the fume ducts (Figure 48-b).
a)
b)
Figure 47
– a) Remove the wing nuts; b) Remove the lid
a)
b)
Figure 48
– a) Vacuuming the interior ; b) Cleaning with a brush
If fumes are not being extracted in the best manner possible, we recommend you clean
the extractor as shown in Figures 49 and 50. However, we recommend that you perform
this procedure at least once a year.