38
Thermostat
This feature allows you to enable or disable the
room temperature thermostat
. Press
“set”. The display starts to flash. Press the “+” or “-” key to select "On" or "Off" and then
“ok” to confirm. Press the "+" key to go to the "Carga Pellet" (Pellet loading) menu.
Pellet loading
This feature allows you to enable the
worm drive
to fill the channel when it is empty to
keep the unit running. Press "set"; the "ok" option appears. Press "ok" to activate the
drive (the "habilitada" (Activated) message appears) and "esc" to stop it. Press the "+"
key to go to the "Limpeza" (Cleaning) menu.
Cleaning
This feature allows you to
clean
the burning basket manually. Press "set"; the "ok"
message appears. Press "ok" to start the cleaning; the "Habilitada" (Activated) message
appears. When you wish to stop, press "ok". Press the "+" key to go to the "Técnico"
(Technical) menu.
Summary of Contents for Alpes 10 kW
Page 22: ...19 b c Figure 17 Examples of standard installations ...
Page 52: ...49 b c d e f g Figure 33 Installation of the UPS kit ...
Page 61: ...58 a b c d e f ...
Page 70: ...67 13 5 Symbols Figure 60 Symbols ...
Page 71: ...68 14 Electrical diagram of the Free Standing Pellet Fire unit Figure 61 Electrical diagram ...