Inverter Display Abbreviation and Complete Name Reference Table
Abbreviation
Complete Name
Safety Set
Select the code that meet local regulatory requirements
Battery_ID Set
Select the battery model
Work Mode
Current work mode / work mode setting
Export Limit
On-grid export limit function switch
Feed in Grid
Set the percentage of the power that is allowed to feed to the grid
On-Off Grid SW
Off-grid function switch (If turn it on, the inverter will automatically switch to off-grid
mode to ensure the back-up side power supply when the gird is abnormal or off, oth-
erwise, there is no output on the back-up side)
Relax OffGrid
Reduce the switching sensitivity of the On/Off-grid (applied to the places where the
grid is unstable or inverter always entered off-grid mode for some reasons)
Offgrid ReConn.
When the power grid is off, the inverter can automatically restart the back-up output
after a fault or overloading protection occurred if the Off-grid restart is ON. Other-
wise, the back-up output needs to be restarted manually
Load Shifting
Peakload shifting function switch
SetMaxGrid
Set max allowed power from grid (under the condition of Peakload Shifting is on)
OnGrid SocProt.
On-grid battery SOC (State of Charge) Protection
OnGrid EndSOC
End-of-discharge SOC of on-grid
OffGrid SocProt.
Off-grid SOC Protection
OffGrid EndSOC
End-of-discharge SOC of off-grid
Unbalan. Output
3-Phase Unbalanced Output Switch when inverter work on On-grid state
System Maint.
System maintenance, includes inverter stop and run, system restart
Multi-INV Role
In the multi-inverter parallel system, set the role of one inverter as the master and the
other inverter as the slave.