![Sole Diesel 68 GTC Operator'S Manual Download Page 43](http://html1.mh-extra.com/html/sole-diesel/68-gtc/68-gtc_operators-manual_1314510043.webp)
SCO 10 Panel
Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · [email protected]
40
Operator’s Manual
. Marine generator sets
•
BI1: Remote control
–
Start or Stop.
•
BI2: Alarm / Temperature switch (shutdown).
•
BI3: Emergency STOP.
•
BI4: Alarm / Pressure switch.
•
BI5: Sd Override.
•
BI6: Exhaust gas temperature (optional kit).
Binary Inputs
–
Binary signals form the genset to the control panel.
Binary Outputs
–
Control panel orders to the genset.
If you do not understand the
description of the alarm it is
recommended to change the language
to English, the original language. If still
in doubt, contact to factory.
•
BO1: Crancking signal (start)
•
BO2: Stop solenoid, f current comes or not. Fuel
Solenoid corresponds to STOP ETR
•
BO3: Air Valves: corresponds to a feed pump
•
BO4: Pre-heating glow plugs
•
BO5: Horn (free, is not wired)
•
BO6: Alarm. If the system detects an alarm (free,
is not wired)
•
The left column shows the active power of
each phase and total current
(if the
amperometric kit is installed).
•
The middle column shows the power factor
of each phase and total current
(if the
amperometric kit is installed).
•
The right column shows the apparent power
of each phase and total.
Summary of Contents for 68 GTC