Systems and scheduled
maintenance
Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · [email protected]
30
Operator’s Manual
. Marine generator sets
9.
Lubricate the gasket with silicon grease and attach the gasket and cover plate to the
seawater pump housing.
10.
Open the seacock.
11.
Start the genset and check for leaks.
5.7. Inlet and Exhaust System
Exhaust circuit description
There are two possible installations of the exhaust system. You need to check the distance between
water injection point and waterline to decide which type of installation you need. This information is
specified in the following drawings.
The elements included in the drawing are essential for the correct genset operation:
-
Waterlock (supplied as accessory) to prevent seawater from entering inside the engine when
it stops.
To calculate the required collector capacity, we must follow the following formula:
-
Goose neck (supplied as accessory)
-
Siphon breaker (supplied as accessory)
–
needed in case there is less than 150 mm
between the water injection point of wet exhaust and the waterline, or if the point of
injection is below waterline.
Type 1 installation. When between water injection point of wet exhaust and waterline is
minimum 150 mm
.
M
A
X
.
1
5
0
0
m
m
M
IN
.
4
5
0
m
m
M
IN
.
5
0
m
m
M
IN
.
1
5
0
m
m
W.L.
L
=
M
IN
. 3
00
m
m
L = MAX. 3000 mm
𝐶
=
𝜋
4
𝐷
2
∗ 𝐿
1000000
∗
0.5
C = collector capacity (L)
D = Inside diameter of the tube (mm)
L = Tube length (mm)