HU-PYXIS
14
PYXIS
System User Guide
A fault signal is available from the fan module relay that can be used within the system as an alarm.
Accessed using the AES/LTC 9-way on the rear panel. See Section 5.1.5 for pin-out details. Details
of setting up the relay are in section 3.1.7.2
3.1.6.2
Replacing the Fan
Figure 8: Replacing a Fan Module
The Fan Module (fan & PCB) is designed for easy replacement.
To replace the fan:-
1. Unplug the power connector. Do not remove the connector or desolder leads. The replacement
assembly comes with a pre-fitted cable and plug.
2. Disconnect the Ribbon Connector.
3. Swing the front door open 30 degrees and remove from the frame.
4. Remove the four corner retaining screws.
5. Remove and replace the fan.
WARNING
Do not operate the frame for long periods without the fan running
and the door closed. High risk of overheating and damage