HU-PYXIS
70
PYXIS
System User Guide
6.5.2.1 Timecode
Routing
Modules
Inputs/Outputs
Output Amplitude
1-2V pk-pk into a 1 k
Ω
load
Output Impedance
50
Ω
nominal
Input Impedance
> 5 k
Ω
Data Rate
50 Hz - 5 MHz
Table 41: Timecode Routing Modules: I/O Specification
6.5.3 User
Interface
Each RS422/Timecode Router has the same user interface (accessible via the front door). In the
left hand corner are 3 RGB LED’s, 2 Hex Switches and 1 Bank of 4 DIP Switches.
Figure 44: RS422/Timecode Modules: LEDs and Switches
6.5.3.1 LED
Description
Name
Color
Function
PWR-OK
Green Power
OK
Red Failure
H/S
(Handshake)
Flashing Amber
(may appear to be red and green LEDs if
viewed at close range)
Indicates communication between
frame controller and module
TAKE
Flashing Amber
(may appear to be red and green LEDs if
viewed at close range)
Indicates a route has been updated
or refreshed
Table 42: RS422/Timecode Modules: LED Functionality