HU-PYXIS
44
PYXIS
System User Guide
6.1.2 User Interface
Each digital video routing module has the same user interface (accessible via the front door). In the
left hand corner are 3 RGB LED’s, 2 Hex Switches and 3 Banks of DIP Switches.
Figure 31: 9200 Range Modules: Switches and LEDs
6.1.2.1 LED
Description
NAME
COLOUR
FUNCTION
PWR-OK
Green Power
OK
Red Failure
H/S
(Handshake)
Flashing Amber
(may appear to be red and green
LEDs if viewed at close range)
Indicates communication between frame
controller and module.
With 2449 Controller 3 or 4 flashes every 10 seconds.
With 2450 Controller will appear as permanently flashing
TAKE
Flashing Amber
(may appear to be red and green
LEDs if viewed at close range)
Indicates a route has been updated or refreshed
Will flash with every route-set command, will flash constantly
if a number of routes are set in rapid succession.
Table 17: 9200 Range Modules: LED Functions
6.1.2.2 Switch
Description
LABEL
TYPE
FUNCTIONALITY
LEVEL
Rotary Hex Switch
Sets modules ‘logical level’ adjusting
port offset (numbering)
(Level & Offsets described in table below)
FACTORY USE
Rotary Hex Switch
Not Used
SLEW RATE
MANUAL OVERRIDE
DIP Switches
(3 Banks of 4-way switches)
Allows user to manually fix output slew
rate (in groups of 8).
(Port mapping & speeds detailed in table below)
Table 18: 9200 Range Modules: Switch Functionality