HU-PYXIS
60
PYXIS
System User Guide
LEDs
Name
Function
PWR_OK
Green = all power rails ok
H/S
Flashes green at about 2Hz when commands are received from controller
TAKE
Lights green for about 1 second when the controller sets a route on this card
Table 32: AES Module: Status LED Functionality
SWITCHES
Name
Type
Function
RESET
Push Button
Manual Reset of Module
MODE
4 Way DIP
Piano Key
DIP
1 OFF
(up)
= 56 channel MADI, ON
(down)
= 64 channel MADI
2 OFF
(up)
= Router mode, ON
(down)
= Transcoder mode
3 OFF
(up)
= lock to reference, ON
(down)
= lock to MADI
4 OFF
(up)
= Fs is not 44.1kHz, ON
(down)
= Fs = 44.1kHz.
DEST OFFEST
Rotary HEX
Destination Offset
(Range 0-3)
LEVEL
Rotary HEX
Module Level
(Range 0-7)
Table 33: AES Module: Configuration Switch Functionality
6.3.1.2 MENU
INTERFACE
Name
Type
Function
OK
Push
Button
Change Menu Mode* (Normal, Input Monitor)
-
+
Push
Button
Select Channel to be modified/monitored
UP
DOWN
Push
Button
2449 Controller and Input Monitor Mode
UP: Force sample rate converter into circuit for
selected channel
DOWN: Return Channel to Auto Mode
Else No Effect
Table 34: AES Module: Menu Switch Functionality