55
EEWB334A
Code C0
Setting the factory-adjusted modes of operation
(
F
5.2.2)
0* =
No action
1 =
Set default values
(state 1 is only shown briefl y)
After the confi rmation
OK
, this operating mode can be
acquired in the permanent memory (
C10
).
Code C1
Selecting the defi nition of the imbalance value in steps
from 0.05 or 0.25 oz. (respectively 1 or 5 grams).
0*
= 0,25 oz (5 grams) defi nition
1
= 0,05 oz (1 gram) defi nition
After the confi rmation
OK
, this operating mode can be
acquired in the permanent memory (
C10
).
Code C2
Selecting suppression of minor unbalance
readings
0 =
Suppression off
1* =
Suppression on
After the confi rmation
OK
, this operating mode can be
acquired in the permanent memory (
C10
).
Code C3
Selecting unbalance readings in grams or ounces,
active when the machine is switched on
1* =
Readings in ounces
0 =
Readings in grams
After the confi rmation
OK
, this operating mode can be
acquired in the permanent memory (
C10
).
Code C4
Electrical compensation of residual unbalance
(
F
6.1)
, if any, in the clamping means:
Measurement with increased precision (this mode
cannot be transferred into the permanent memory).
Compensation has to be cancelled and carried out
once again when the clamping means is exchanged.
* = Factory adjusted mode
Resetting the status to 0 cancels the compensation of
adaptor unbalance.
The compensation is canceled by calibration, or
readjustment of the machine, by optimization, or when
the machine is turned off.
Code C5
Braking of the wheel when the wheel guard is
opened during the measuring run
0 =
No braking
THE WHEEL ROTATES WHEN THE WHEEL GUARD
IS OPEN.
MAKE SURE THAT THE WHEEL IS NOT BLOCKED
BY A TOOL OR SIMILAR ITEM.
WEAR SAFETY GOGGLES AND TIGHTLY FITTING
WORKING CLOTHES.
1* =
Braking
After the confi rmation
OK
, this operating mode can be
acquired in the permanent memory (
C10
).
Code C6
Number of revolutions per measuring run 5 to 25
revolutions possible, factory–set to 10*
Note:
Reducing the number of measurement
revolutions will reduce the accuracy
of measurement. The selected mode
of operation can be transferred to the
permanent memory.
After the confi rmation
OK
, this operating mode can be
acquired in the permanent memory (
C10
)
Code C8
Selecting the limit (threshold) value for suppression
of minor unbalance readings in grams, or ounces.
The unit
(g or oz)
depends on the settings made
under C3.
Ounces:
Range: 0.12 to 0.71 oz
Factory-adjusted to 0.18* oz
Select another limit, e. g.: 0.50 oz
•
Select Code C8
•
Set the value 0.50
•
Press
OK