6.3
Storage
When the unit will be stored for a several weeks or
longer prepare the unit correctly:
•
Shut down the unit properly,
F
5.2.4.
•
Remove the threaded shaft from the balancer.
•
Apply a thin layer of non-corrosive oil on all threads
and cones.
•
Wrap oiled items in paper to keep the parts dust-
free.
Before putting the unit into use again, clean all oiled
parts.
6.4 Changing the Main Fuse
Refer to
Figure 6-7
.
•
Switch off the unit.
•
Unplug the power cable from the power outlet.
•
Remove the power cable from the machine main
socket (
1, Fig. 6-7
).
•
Pull out the fuse holder (
2, Fig. 6-7
).
•
Replace the damaged fuse with another fuse that
has an identical rating.
•
Return the unit to its original functioning state, by
following the steps above in reverse.
6.5
Monitor Calibrating
Follow the fi gures
6.8
(
1
,
2
,
3
).
Keeping the
STOP
key pressed for more than 3
seconds in the Introduction screen the calibration
process starts. The process is performed in 3 stages.
The operator must touch in three different times the
white dot with the cross indicator shown on the screen.
First stage;
•
Touch the top left dot (
A
).
Second stage;
•
Touch the middle right dot (
B
).
Third stage;
•
Touch the centre bottom dot (
C
).
At the end of the calibration process, the machine
restarts automatically.
The Touch Screen is now operational.