TRAK MODEL 9100 MODULAR FREQUENCY/TIME SYSTEM
TM4400013
Rev.
D
1-4
1-5
PHYSICAL DESCRIPTION
The Model 9100 is a single chassis designed for mounting in a standard EIA 19-inch wide rack. Front panel
height is 5.22 inches (3U) and overall depth is 15.0 inches exclusive of front panel handles and rear panel
connectors.
There are 12 front panel plug-in modules locations, A1 and A2 are reserved for the GPS Reference Modules, A3
through A8 are reserved for distribution modules, A9 and A10 are reserved for FSU modules and A11 and A12
are reserved for Power Supply modules. Weight is approximately 25 pounds with all modules installed. System
status indicators and test points are located on module front panels. All connections to the unit are via rear
panel connectors with exception of the Telecom module, which contains two front panel high-density 15-pin DD-
sub connectors for Framed and EIA-RS-422 output signals.
1-6 ENVIRONMENTAL
CHARACTERISTICS
Unless otherwise specified, Model 9100 meets all published specifications when operated over the temperature
range of –30°C to +60°C with a rate of change <2°C/minute. Maximum operating humidity is 95%, non-
condensing. The unit withstands normal shock and vibration found in all forms of common-carrier shipment.
1-7 POWER
REQUIREMENTS
The Model 9100 operates from 100 to 240 VAC ± 10%, 48-63 Hz single-phase power. Power consumption with
all modules installed is approximately 120 watts at power-up and tapers to approximately 80 watts within fifteen
minutes of power-up at 25°C.
As an option, the system can be ordered with DC power supply in place of the AC power supply. Input voltage is
20-60 VDC. Refer to Appendix D for further details.
1-8 EMC/EMI
The Model 9100 meets the requirements of FCC Part 15 Class B for North America and Product Family
harmonized standards EN55022 and EN55024 for emissions and immunity compliance of the EMC Directive
89/335/EEC and its amendments.
Note: In order to comply with the standards above, the following interface cables or equivalent listed in Table 1-1
must be used.
Table 1-1 Interface Cables for EMC Compliance
Reference Designator
Connector
Interface cable type
J1 & J2
“N” Type
RG-58
J5 through J28
BNC
RG-400
J29 & J30
RJ-45
Shielded twisted pair
J31 & J32
9-Pin D-SUB
Shielded twisted pair
J33
24 pin
TRAK supplied cable
FL1 & FL2
IEC-320
TRAK supplied power cords
Telecom Module J1 & J2
HD 15-pin DD-SUB
Shielded twisted pair
1-9
INPUT and OUTPUT CHARACTERISTICS
The Model 9100 input and output characteristics are listed in Tables 1-2 through 1-6.