B-5
TM4400013
REV.
D
B-4
9104-9 and Above Setup
The 9104-9 and above is configured through the command line interface using RS-232 I/O port or through the
Ethernet port using Telnet or SSH. This module may also be setup by uploading the entire configuration file. To
remove a setting, an asterisk * may be entered for an IP address, NETMASK, or GATEWAY. Section B-5
describes the command line interface setup and B-6 describes the configuration file upload.
B-5
Command Line Interface Setup
Command line interface setup can be accomplished through the RS-232 I/O, Telnet (if enabled) or SSH.
Request main configuration setup
Host
sends:
cfg
<CR>
9100
replies:
********************************************
* CONFIGURATION SETTINGS *
********************************************
NETWORK SETTINGS
==================
IPADDR 10.1.5.250
NETMASK 255.255.252.0
GATEWAY *
INETD PROTOCOLS
================
IDLE-TIMEOUT
(MINS)
ON/OFF DISCONNECT
DISABLE
-----------
---------------------
-------------
SSH
ON
30
--
TELNET OFF
10
0
TFTP OFF
--
0
HTTP OFF
--
0
SYSTEM SETTINGS
----------------------------
RQFS OFF
SYSLOG SETTINGS
---------------------------
REMOTE *
LOG_MASK 7F -> (7) LOG_DEBUG OFF
(6) LOG_INFO ON
(5) LOG_NOTICE ON
(4) LOG_WARNING ON
(3) LOG_ERR ON
(2) LOG_CRIT ON
(1) LOG_ALERT ON
(0) LOG_EMERG ON