background image

SMCCO10-Z CO Alarm User Guide  

 

 

Copyright 

©

2013 SMC Networks

  

Page 2 

 

All Rights Reserved 

I/M SMCCO10-Z rev. 1.0 

1/24/2013 

1  

 

Parts List 

Your SMCCO10-Z package includes: 

 

One SMCCO10-Z Carbon Monoxide 
Alarm 

 

Three AA alkaline batteries 

 

Mounting plate 

 

Mounting screws and anchors 

 

This User Guide 

2  

 

Mounting Guidelines 

Recommended Locations 

Mount the SMCCO10-Z alarms in or near 
bedrooms and living areas. We 
recommend you install an alarm on each 
level of your home. 
When choosing installation locations, be 
sure you can hear the alarm from all 
sleeping areas. If you install only one 
SMCCO10-Z in your home, install it near 

bedrooms, not in the basement or 
furnace room. Place the alarm out of 
reach of children. Never allow children 
to handle the SMCCO10-Z. 

 

Figure 1. Recommended Locations 

Locations to Avoid 

Selecting an improper location can affect 
the sensitive electronic components in 
your SMCCO10-Z. To avoid damaging the 
unit, to provide optimum performance, 
and to prevent unnecessary nuisance 
alarms, do not install the SMCCO10-Z: 

 

In kitchens, garages, or furnace 
rooms that can expose the sensor to 
substances that can damage or 
contaminate it. 

 

In areas where the temperature is 
colder than 40°F (4.4°C) or hotter 
than 100°F (37.8°C) such as crawl 
spaces, attics, porches, and 
garages. 

 

Within 5 feet of heating or cooking 
appliances. We recommend 15 feet 
to prevent nuisance alarms. 

 

Near vents, flues, chimneys, or any 
forced/unforced air ventilation 
openings. 

 

On metal surfaces. 

 

In areas with a large quantity of 
metal or electrical wires. 

 

Near ceiling fans, doors, windows, 
or areas directly exposed to the 
weather. 

Summary of Contents for SMCCO10-Z

Page 1: ...the system is monitored The SMCCO10 Z also detects low battery wall tamper and sensor end of life These trouble codes are sent to the Touchscreen which reports the condition to the central monitoring...

Page 2: ...dren Never allow children to handle the SMCCO10 Z Figure 1 Recommended Locations Locations to Avoid Selecting an improper location can affect the sensitive electronic components in your SMCCO10 Z To a...

Page 3: ...A Log in to the Settings app with an Installer code B In the Settings menu tap Sensors Zones Add a Sensor Zone C Place the SMCCO10 Z in Search mode and prepare it to be added to the Touchscreen refer...

Page 4: ...Sensors screen M If all sensors have not been configured the Modify screen appears for each sensor to let you review its details Change the details as needed or tap Next to cycle through all the sens...

Page 5: ...ded Place one label next to the SMCCO10 Z after it is mounted and the other label near a fresh air source such as a door or window 5 Installng RepacingBatteries The SMCCO10 Z comes with 3 batteries pr...

Page 6: ...uct is sealed and its cover is not removable The SMCCO10 Z alarm has 3 test modes Normal CO alarm test conducts an internal self test and tests the sounder See Running the Normal CO Alarm Test on page...

Page 7: ...ion A Be sure the SMCCO10 Z is operating normally and the green Power LED is flashing once every 30 seconds B Wait at least 10 minutes after installing the SMCCO10 Z C Set the Touchscreen to sensor te...

Page 8: ...ow When CO is detected the SMCCO10 Z activates a CO alarm The SMCCO10 Z sends RF test packets to the Touchscreen when the CO alarm activates Figure 6 CO Testing Slit F The Touchscreen beeps and shows...

Page 9: ...stem is disarmed The system continues to log the activity of bypassed zones in the Event History see View Zone Event History on this page To bypass a zone A With the system disarmed tap the Security a...

Page 10: ...correct Check the battery voltage 1 5 VDC nominal per battery Touchscreen does not respond Use a wireless RF sniffer to confirm that the SMCCO10 Z is sending messages for activation Be sure the SMCCO1...

Page 11: ...Standby Current 35 A typically Battery Life 5 years typically Sensor Life 10 years Alarm Response Time 70 PPM 60 240 min 150 PPM 10 50 min 400 PPM 4 15 min Audible alarm 85 dBa 10 3M temporal 4 Low B...

Page 12: ...Test Hush button and release to silence the end of life signal for up to 3 days After 3 days unit resumes end of life chirps Hush mode silences the alarm 10 times or up to 30 days After 30 days the un...

Page 13: ...solvents to clean the SMCCO10 Z They can permanently damage or temporarily contaminate the sensor Avoid spraying air fresheners hair spray paint or other aerosols near the product Do not paint the SMC...

Page 14: ...t you to the presence of CO before most people would experience symptoms of CO poisoning giving you time to resolve the problem calmly Determine whether anyone is experiencing symptoms of CO poisoning...

Page 15: ...sent the sooner the alarm is triggered Your SMCCO10 Z can only warn you about the presence of CO It does not prevent CO from occurring and cannot solve existing CO problems If your SMCCO10 Z has alarm...

Page 16: ...its It is not designed to measure compliance with Occupational Safety and Health Administration OSHA commercial or industrial standards It is not suitable for installation in hazardous locations as de...

Page 17: ...ompliant This product does not contain lead mercury cadmium hexavalent chromium polybrominated biphenyls PBB or polybrominated depheny ethers PBDE in more than the percentage specified by EU directive...

Reviews: